The two new members of the renowned Modular Compact Rheometer (MCR) series – MCR 72 and MCR 92 – are the two wisest choices for quick and easy rheological measurements. These real rheometer “pearls” from Anton Paar are streamlined for your daily lab routine, easy to use in a plug-and-play fashion, and available at an accommodating price. There is a range of accessories available for both models. The step-by-step software and special features like TruRay (integrated light), QuickConnect (fast and easy mounting of the measuring system), Toolmaster™ (automatic tool recognition and configuration), etc. guarantee excellent ease of use. For academic use, both instruments are available as an EDU Edition, including a special EDU package for teaching staff as well as EDU Student Packages.
MCR 72
The robust one
Equipped with a ball bearing motor
For measurements in rotation (and oscillation for special applications)
Ideal to measure your samples’ flow behavior
MCR 92
The sensitive one
Equipped with a highly accurate air bearing motor for sensitive samples
Two new rheometers are available: MCR 72 is equipped with a ball-bearing motor (very robust in use, no compressed air required) and MCR 92 with an air-bearing motor (highly accurate for sensitive samples). The two rheometers enable measurements in both rotational and oscillatory mode. The choice of rheometer depends on your application. To investigate the deformation and flow behavior of your sample (also at different temperatures), consider MCR 72. For observing sample structure, MCR 92 is recommended. Both instruments have a motor that lifts up the measuring head automatically to set an exact measuring gap. This gap is 100 % reproducible. MCR 72 and MCR 92 can both be equipped with temperature devices to cover a range from -50 °C to +400 °C.
Your key to accuracy – the motor technology
25 years of experience in one motor – you only get this with rheometers from Anton Paar. The air-bearing-supported synchronous EC motor deploys a frictionless synchronous movement of the rotor inside that enables the most sensitive and therefore most precise movements. Whether investigating solids or low-viscosity liquids your results are accurate across a wide viscosity range.
Step-by-step software
The intuitive RheoCompass™ software helps you to find the test template you need, customize tests and analysis definitions, export your data and generate reports. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos and pictures for extra support. Different accounts can be created for each operator working in the lab.
Unique features for easy handling and reproducible results
The highlight of these two rheometer models is the patented TruRay lighting of the measuring surface, which can be gradually regulated for a clear view of your sample. When changing between measuring systems, QuickConnect allows one-handed connection of the measuring systems and ensures fast, convenient system changes without the use of a screwing mechanism. Then, Toolmaster™ takes over by automatically recognizing the mounted tool and temperature units. Finally, the SafeGap feature ensures that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time.
Experienced experts close to you
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. One thousand installed instruments around the globe, an extensive application database, a website full of practical information (World of Rheology), the book “Applied Rheology – With Joe Flow on Rheology Road”, eLearning courses and numerous published works by our rheology experts confirm that Anton Paar is the first choice for answering any rheological question you may have.
Technical specifications
Specifications
Units
MCR 72
MCR 92
Bearing
–
Ball
Air
EC motor (brushless DC) with high resolution optical encoder
–
✔
✔
Rotation Mode
–
✔
✔
Oscillation Mode
–
✔(1
✔
Direct Strain Controller
–
✔
✔
Direct Stress Controller
–
✔
✔
Maximum torque
mNm
125
125
Minimum torque, rotation
µNm
200
1
Minimum torque, oscillation
µNm
200
1
Torque resolution
nNm
100
100
Angular deflection, set value
µrad
1 to ∞
1 to ∞
Angular deflection, resolution
nrad
614
614
Step rate, time constant
ms
100
100
Step strain, time constant
ms
100
100
Minimum angular velocity (2
rad/s
10-Apr
10-Apr
Maximum angular velocity
rad/s
157
157
Minimum angular frequency (3
rad/s
10-Mar
10-Apr
Maximum angular frequency
rad/s
628
628
Minimum speed (CSS/CSR)
rpm
10-Mar
10-Mar
Maximum speed
rpm
1500
1500
Maximum temperature range
°C
-50 to +400
-50 to +400
SafeGap, Normal force Limiter during Gapsetting
–
✔
✔
TruRay, Dimmable illumination of sample area
–
✔
✔
Connections
USB, Ethernet, RS232, Analog interfaces, Pt100 port
Dimensions
mm
380 x 660 x 530
380 x 660 x 530
Weight
kg
33
33
QuickConnect for measuring systems, screwless
–
✔
✔
ToolmasterTM, measuring system
–
✔
✔
ToolmasterTM, measuring cell
–
✔
✔
CoolPeltierTM, Peltier-controlled Plate System with built in cooling option that requires no additional accessories for counter-cooling
°C
25 below ambient temperature but not lower than -5 up to +200 (4
Actively Peltier-controlled hood that requires no additional accessories for counter-cooling
°C
-5 to 200 (4
CoolPeltierTM, Peltier-controlled Cylinder System with built in cooling option that requires no additional accessories for counter-cooling
°C
15 below ambient temperature but not lower than +5 up to +150 (4
Virtually gradient-free (horizontal, vertical) temperature control
Modular Compact Rheometer: MCR 72/92
The two new members of the renowned Modular Compact Rheometer (MCR) series – MCR 72 and MCR 92 – are the two wisest choices for quick and easy rheological measurements. These real rheometer “pearls” from Anton Paar are streamlined for your daily lab routine, easy to use in a plug-and-play fashion, and available at an accommodating price. There is a range of accessories available for both models. The step-by-step software and special features like TruRay (integrated light), QuickConnect (fast and easy mounting of the measuring system), Toolmaster™ (automatic tool recognition and configuration), etc. guarantee excellent ease of use. For academic use, both instruments are available as an EDU Edition, including a special EDU package for teaching staff as well as EDU Student Packages.
MCR 72
MCR 92
Description
Key features
Two new rheometers are available: MCR 72 is equipped with a ball-bearing motor (very robust in use, no compressed air required) and MCR 92 with an air-bearing motor (highly accurate for sensitive samples). The two rheometers enable measurements in both rotational and oscillatory mode. The choice of rheometer depends on your application. To investigate the deformation and flow behavior of your sample (also at different temperatures), consider MCR 72. For observing sample structure, MCR 92 is recommended. Both instruments have a motor that lifts up the measuring head automatically to set an exact measuring gap. This gap is 100 % reproducible. MCR 72 and MCR 92 can both be equipped with temperature devices to cover a range from -50 °C to +400 °C.
Your key to accuracy – the motor technology
25 years of experience in one motor – you only get this with rheometers from Anton Paar. The air-bearing-supported synchronous EC motor deploys a frictionless synchronous movement of the rotor inside that enables the most sensitive and therefore most precise movements. Whether investigating solids or low-viscosity liquids your results are accurate across a wide viscosity range.
The intuitive RheoCompass™ software helps you to find the test template you need, customize tests and analysis definitions, export your data and generate reports. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos and pictures for extra support. Different accounts can be created for each operator working in the lab.
The highlight of these two rheometer models is the patented TruRay lighting of the measuring surface, which can be gradually regulated for a clear view of your sample. When changing between measuring systems, QuickConnect allows one-handed connection of the measuring systems and ensures fast, convenient system changes without the use of a screwing mechanism. Then, Toolmaster™ takes over by automatically recognizing the mounted tool and temperature units. Finally, the SafeGap feature ensures that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time.
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. One thousand installed instruments around the globe, an extensive application database, a website full of practical information (World of Rheology), the book “Applied Rheology – With Joe Flow on Rheology Road”, eLearning courses and numerous published works by our rheology experts confirm that Anton Paar is the first choice for answering any rheological question you may have.
Technical specifications
Standards
ASTM
DIN
DIN EN
EN
ICA
IOCCC
ISO
Pharmacopoeia Europe (Ph. Eur.)
U.S. Pharmacopoeia (USP)
Related products
Particle size analyzer: PSA
Read moreDensity meter: DMA 4200 M
Read moreMicrowave digestion platform: Multiwave 5000
Read more